Engineering Rules

Configure validation rules applied to all AV system designs

Total Rules

27

Active

26

Disabled

1

Custom

0

27 of 27 rules

Validation Rules
Rule NameCategorySeverityDescriptionActiveCan Override

PDU Power Capacity (80% Rule)

RackError

Rack power load must not exceed 80% of PDU capacity to maintain safe headroom

Rack Ventilation Spacing

RackWarning

Rack must include 1U ventilation panel between heat-generating devices such as amplifiers and encoders

Rack Floor Load Compliance

RackError

Fully populated rack weight must not exceed the rated floor load of the installation environment

Cable Management Reserve

RackWarning

Rack must have minimum 2U reserved for horizontal cable management panels

UPS Bottom Placement

RackInfo

UPS unit must be positioned at the bottom of the rack to maintain low center of gravity

Circuit Capacity Compliance

PowerError

Total system power draw must not exceed the rated capacity of the dedicated circuit

PoE Switch Budget

PowerError

Aggregate PoE device power draw must not exceed the total PoE budget of the switch

PDU Headroom Requirement

PowerWarning

PDU must support 20% headroom above calculated total load for expansion and safety

Mission-Critical Redundant Power

PowerWarning

Redundant power feed and UPS protection required for mission-critical AV systems

Dante Dedicated VLAN

NetworkError

All Dante audio-over-IP devices must be isolated on a dedicated VLAN separate from corporate traffic

IGMP Snooping for AV-over-IP

NetworkError

Multicast IGMP snooping must be enabled on all switches carrying AV-over-IP multicast traffic

PoE Class Match

NetworkError

Network switch port PoE class (802.3af/at/bt) must match the power requirement of the connected device

QoS for Real-Time AV

NetworkWarning

QoS DSCP markings must be configured to prioritize real-time AV traffic on all managed switches

DM-NVX Redundant Network Path

NetworkWarning

Redundant network path required for Crestron DM-NVX deployments in mission-critical spaces

HDMI Cable Length Limit

CableError

Passive HDMI cable length must not exceed 15m; extender or active cable required for longer runs

Cat6 Horizontal Run Limit

CableError

Cat6 horizontal cable runs must not exceed 100m per TIA-568 standard

HDBaseT Cable Length Limit

CableError

HDBaseT signal extension over Cat6A must not exceed 100m for 4K/HDR signal integrity

DSP Input Source Completeness

SignalWarning

All active DSP input channels must have a configured source connection in the signal flow

Display Input Source Completeness

VideoWarning

All display inputs designated as active must have a corresponding source in the signal chain

Speaker Impedance Match

AudioError

Speaker load impedance must match the rated output impedance range of the connected amplifier

Amplifier Power Headroom

AudioError

Amplifier continuous power output must not exceed the RMS power handling capacity of the speaker

AEC Reference Path Required

AudioError

AEC reference signal must be routed between DSP output and conferencing codec loudspeaker return

Speaker Coverage Minimum

AudioWarning

Speaker coverage per AVIXA 4OHMS must achieve minimum 85% of primary seating area

Ceiling Mic Spacing

AudioWarning

Ceiling microphone spacing must comply with manufacturer maximum pickup radius recommendations

Touch Panel ADA Mounting Height

ADA ComplianceWarning

Touch panel mounting height must comply with ADA: operable parts at 48" AFF maximum (side reach 54" AFF)

Assistive Listening Requirement

ADA ComplianceWarning

Assistive listening system (hearing loop or FM/IR) required for assembly spaces with occupancy exceeding 50

Interactive Display ADA Height

ADA ComplianceInfo

Bottom edge of interactive display must not exceed 48" AFF when forward-reach clearance is provided